Server Layer

Stack layer · Compute trays, servers and rack integration · Global, with US assembly

The server is where accelerators, memory, networking and power become a machine a factory can ship. It is also the first layer of the stack where US assembly can be counted: Foxconn in Houston and Wistron in Dallas-Fort Worth build Nvidia AI servers.

Schematic elevation of an Nvidia GB200 NVL72 rack: power shelves at top and bottom, 18 compute trays split around 9 NVLink switch trays, and a liquid cooling manifold on the side POWER SHELVES COMPUTE TRAYS 2 CPUS + 4 GPUS EACH NVLINK SWITCH TRAYS ONE FABRIC, 72 GPUS COMPUTE TRAYS 18 IN THE RACK POWER SHELVES LIQUID COOLING MANIFOLD SCHEMATIC, NOT TO SCALE
Reference platform
GB200 NVL72
GPUs per rack
72
AI server power
2-5 kW
Cooling
Direct-to-chip
US assembly
Houston, DFW
Layer
Server

Overview

A Server Combines Compute, Memory, Storage, Networking and Power in One Chassis

The server is the basic building block of the data center. In AI data centers, servers are high-density machines built around accelerators, liquid cooling and multi-kilowatt power envelopes, from Nvidia DGX and HGX systems to Dell PowerEdge and Supermicro GPU servers.

At rack scale the server dissolves into the rack. In an Nvidia GB200 NVL72, 18 compute trays and 9 NVLink switch trays form a single 72-GPU machine, so the unit that ships, gets installed and gets cooled is the whole rack.

  • Form factors: 1U and 2U rackmount servers, blade enclosures and Open Compute Project (OCP) sleds dominate hyperscale. AI training servers often use 4U chassis for 8 GPUs.
  • Compute density: CPUs and GPUs draw 500 to 1,000 W each, pushing server power into the 2 to 5 kW range and driving the shift to liquid cooling.
  • Interconnect: PCIe Gen5, NVLink and CXL (Compute Express Link) tie accelerators, CPUs and pooled memory together at high bandwidth and low latency.
  • Storage: NVMe SSDs and NVMe-oF adapters have replaced SATA and SAS, so local storage does not hold back GPU workloads.
  • Open standards: OCP hardware, open firmware and modular platforms reduce vendor lock-in.

AI and enterprise servers

AI Training Servers Run at Several Times the Power of Enterprise Servers

AI training servers differ from enterprise servers in power, cooling, architecture and workload.

AI training and general-purpose enterprise servers
DimensionAI training serversEnterprise servers
Primary workloadLarge-scale AI training and inferenceVirtualization, databases, business applications
ComputeAccelerator-dense, 8 GPUs per chassis or 4 per rack-scale trayCPU-centric, 2-4 sockets
MemoryHBM plus large DDR5 and CXL expandersDDR4 and DDR5, smaller per node
StorageNVMe SSDs and NVMe-oF, tuned for throughputSSD and HDD mix, tuned for capacity
Networking400-800G Ethernet, InfiniBand, NVLink10-25G Ethernet, some 100G uplinks
Power envelope2-5 kW per server500-800 W per server
CoolingLiquid, cold plates, immersion-readyAir, fans and heat sinks
Cost$250K-$500K per node$5K-$25K per node

Platform supplier ring

The GB200 NVL72 Ring Is Drawn Once and Applies Wherever the Rack Is Installed

Campus supplier rings rarely name the server builder, the switch maker or the optics supplier, because those are chosen at the platform, not the site. DatacentersX draws the ring at the platform: one ring per rack-scale or pod-scale machine, with a US-made share for each layer.

  • Chips and memory
  • Server and rack
  • Network and optics
  • Cooling
  • Power
GB200 NVL72 supplier ring by layer
LayerWhat it suppliesNamed suppliersUS-made share
Chips and memoryBlackwell GPUs, Grace CPUs, HBMNvidia, TSMC; SK hynix, Samsung, Micron (see SemiconductorX)Placeholder
Server and rackCompute trays, rack integrationFoxconn, Quanta, Wiwynn, Wistron, Supermicro, DellPlaceholder
Network and opticsNVLink switch trays, Spectrum-X and InfiniBand switches, transceiversNvidia; Coherent, InnoLight, EoptolinkPlaceholder
CoolingCold plates, manifolds, coolant distribution unitsVertiv, CoolIT, MotivairPlaceholder
PowerPower shelves, busbarDelta, Lite-OnPlaceholder
Placeholder: full ring from the platform rings dataset, with evidence per supplier

Texas campuses running GB200 racks, such as Stargate Abilene, link here for the compute layer of their rings.

Vendors

Chip Vendors Set the Platform, OEMs and ODMs Build It

Chip vendors design the reference platform. OEMs (original equipment manufacturers) sell branded servers to enterprises; ODMs (original design manufacturers) build white-label servers in volume for hyperscalers.

  • Chip platform
  • OEM
  • ODM
Notable server vendors
VendorPlatformForm factorKey features
NvidiaDGX and HGX; GB200 NVL724U GPU server; rack-scale8 GPUs per HGX board, NVLink and NVSwitch fabric
AMDInstinct MI300X and MI355X platforms4U GPU server8 GPUs, Infinity Fabric, CXL support
IntelGaudi and Xeon servers2U-4U rackmountAccelerator with integrated Ethernet, CPU-centric options
SupermicroGPU-optimized line4U rackmount, rack-scaleUp to 10 double-width GPUs, PCIe Gen5, US manufacturing in San Jose
Dell TechnologiesPowerEdge XE9680 and XE97124U rackmount, rack-scale8 GPUs, liquid cooling option
HPECray EX, ProLiant DL380aBlade, 2U rackmountHPC and AI hybrid
LenovoThinkSystem SR670 V23U rackmountUp to 8 GPUs, Neptune liquid cooling
InspurNF5688 series4U rackmount8 GPUs, leading supplier to China hyperscalers
FoxconnNvidia compute trays and racksRack-scaleLargest AI server ODM; Houston assembly
Quanta (QCT)QuantaGrid line2U rackmount, rack-scaleODM for hyperscalers
WiwynnOCP GPU nodesOCP sledsHigh-volume ODM for cloud providers
WistronNvidia compute traysRack-scaleDallas-Fort Worth assembly

Bill of materials

Eight Domains Make Up an AI Server

Typical AI server bill of materials
DomainExamplesRole
ComputeNvidia Blackwell, AMD Instinct; Intel Xeon, AMD EPYC, Nvidia Grace; custom ASICsTraining and inference performance
MemoryHBM, DDR5 DIMMs, CXL expandersHolds large models and datasets
StorageNVMe SSDs, U.2 and U.3 drives, M.2 boot modulesLocal high-speed persistence
NetworkingEthernet and InfiniBand NICs, SmartNICs and DPUs, PCIe Gen5Connects the server to the rack and cluster fabric
PowerAC/DC and 48 VDC supplies, VRMs, redundant pairsConverts and conditions incoming power
CoolingCold plates, direct-to-chip loops, immersion-ready chassisRemoves concentrated heat
Form factorRackmount, 4U GPU servers, OCP sleds, compute traysSets how the server fits the rack
Management and securityBMC, TPM, secure bootTelemetry, remote management, hardware trust

Constraints

Power, Heat, Interconnect and HBM Supply Set the Pace

  • Power draw: servers reach 5 kW and racks pass 100 kW, which calls for busbars, high-density PDUs and liquid distribution. See Power Distribution.
  • Heat: cold plates and direct-to-chip loops are now standard because air cannot carry the load. See Direct-to-Chip Cooling.
  • Interconnect: PCIe lane limits and latency still constrain GPU clusters; NVLink and CXL fabrics are the response.
  • Supply: GPUs and HBM face long lead times and capacity limits. See the Bottleneck Atlas.

Outlook

Disaggregation and Liquid Cooling Lead the Next Generation

  • Disaggregation: compute, memory and storage split into composable pools over CXL and Ethernet fabrics.
  • Accelerator diversity: TPUs, Trainium and other custom silicon spread alongside GPUs.
  • Liquid by default: immersion-ready and cold-plate chassis become standard as thermal loads rise.
  • US assembly: more of the server and rack layers move to Texas and other US sites, tracked in the platform rings.